Technical note Open Access

Structural analysis of the double-walled copper-steel cryogenic chamber of the ASTAROTH experiment

Daniele Cortis; Donato Orlandi; Andrea Zani; Davide D'Angelo


JSON-LD (schema.org) Export

{
  "@context": "https://schema.org/", 
  "@id": "https://doi.org/10.15161/oar.it/143355", 
  "@type": "ScholarlyArticle", 
  "creator": [
    {
      "@id": "https://orcid.org/0000-0003-4272-7083", 
      "@type": "Person", 
      "affiliation": "INFN LNGS", 
      "name": "Daniele Cortis"
    }, 
    {
      "@id": "https://orcid.org/0000-0002-5567-792X", 
      "@type": "Person", 
      "affiliation": "INFN LNGS", 
      "name": "Donato Orlandi"
    }, 
    {
      "@id": "https://orcid.org/0000-0002-7507-7657", 
      "@type": "Person", 
      "affiliation": "INFN Milano", 
      "name": "Andrea Zani"
    }, 
    {
      "@id": "https://orcid.org/0000-0001-9857-8107", 
      "@type": "Person", 
      "affiliation": "INFN Milano", 
      "name": "Davide D'Angelo"
    }
  ], 
  "datePublished": "2023-10-31", 
  "description": "<p>This document describes the verification process of structural performance of the double- walled copper-steel cryogenic chamber of the ASTAROTH (All Sensitive crysTal ARray with lOw THreshold) experiment and the evaluation of the stresses generated near the thermal bridge connecting the inner and outer wall. The chamber consists of an external AISI 316L stainless steel dewar and an inner double-walled OF (Oxygen Free) copper dewar connected to an AISI 316L stainless steel flanged collar. The results showed that close to the thermal bridge (copper-steel junction) the stresses slightly exceed the YS of copper at the estimated operating temperature (localised strain-hardening condition). On the other hand, the safety coefficient respect to fracture is well above one for both materials. This condition, together with the fact that limited cooling cycles are expected during the operating life of the system, leads to the assumption that a progressive material hardening will occur in this area, thus locally raising the YS limit.</p>", 
  "headline": "Structural analysis of the double-walled copper-steel cryogenic chamber of the ASTAROTH experiment", 
  "identifier": "https://doi.org/10.15161/oar.it/143355", 
  "image": "https://zenodo.org/static/img/logos/zenodo-gradient-round.svg", 
  "inLanguage": {
    "@type": "Language", 
    "alternateName": "eng", 
    "name": "English"
  }, 
  "keywords": [
    "ASTAROTH", 
    "Structural analysis", 
    "Thermal analysis", 
    "Dewar", 
    "Stainless steel", 
    "Copper"
  ], 
  "license": "https://creativecommons.org/licenses/by/4.0/", 
  "name": "Structural analysis of the double-walled copper-steel cryogenic chamber of the ASTAROTH experiment", 
  "url": "https://www.openaccessrepository.it/record/143355"
}